Phase 1 — nur Referenz und Identifikation. Kein Shop, keine Konten.
DINStatus unklarEntwurf · eine Quelle

DIN 7967

Sicherungsmuttern (Palmuttern)

Nationale Entsprechungen
UNI 8835
Festigkeitsklassen
A2A4
Werkstoffe
StahlEdelstahl

Maße

mm · Werte wie in der Norm angegeben
GrößePdddsemfffmassuv
M40.7
3.5
—
—
7
h13
≈ 8.1
2.5
0.3
—
—
0.17
≥ 2.5
≥ 5.7
M50.8
4.5
—
—
8
h13
≈ 9.2
2.5
0.4
—
—
0.28
≥ 2.5
≥ 6.5
M61
5.3
—
—
10
h13
≈ 11.5
3
0.4
—
—
0.4
≥ 3
≥ 8
M81.25
6.9
7.1
—
13
h13
≈ 15
3.5
0.5
0.4
—
0.7
≥ 3.5
≥ 10
M101.5
8.6
9
9.3
17
h13
≈ 19.5
4
0.5
0.5
0.5
1.4
≥ 4
≥ 12
M121.75
10.4
10.7
11
19
h13
≈ 21.9
4.5
0.6
0.6
0.6
1.9
≥ 4.5
≥ 14.5
M142
12
12.7
—
22
h13
≈ 25.4
5
0.6
0.6
—
2.5
≥ 5
≥ 16
M162
14.1
14.8
—
24
h13
≈ 27.7
5
0.7
0.7
—
3.4
≥ 5
≥ 18
M182.5
15.5
16.2
16.8
27
h13
≈ 31.2
5.5
0.7
0.7
0.7
4.1
≥ 5.5
≥ 20.5
M202.5
17.6
18.3
18.8
30
h13
≈ 34.6
6
0.8
0.8
0.7
5.1
≥ 6
≥ 22
M222.5
19.6
20.3
20.8
32
h13
≈ 36.9
6
0.8
0.8
0.7
5.6
≥ 6
≥ 24
M243
21
22.5
22.8
36
h13
≈ 41.6
7
0.9
0.9
0.7
7.4
≥ 7
≥ 26
M273
24.2
25.5
—
41
h13
≈ 47.3
7
1
1
—
13
≥ 7
≥ 29
M303.5
26.6
28.5
—
46
h13
≈ 53.1
8
1.1
1
—
16
≥ 8
≥ 32
M333.5
29.8
31.5
—
50
h13
≈ 57.7
8
1.2
1
—
18.5
≥ 8
≥ 34
M364
32.2
33.6
—
55
h13
≈ 63.5
9
1.3
1.3
—
29
≥ 9
≥ 38
M394
35.2
36.6
—
60
h13
≈ 69.3
9
1.3
1.3
—
32
≥ 9
≥ 40
M424.5
37.6
39.8
—
65
h13
≈ 75
11
1.4
1.4
—
45
≥ 11
≥ 45
M454.5
40.9
42.8
—
70
h13
≈ 80.8
12
1.5
1.5
—
64
≥ 12
≥ 48
M485
43.9
45.8
—
75
h13
≈ 86.5
14
1.6
1.5
—
75
≥ 14
≥ 52
M525
48.2
49.8
—
80
h13
≈ 92.4
16
1.7
1.5
—
80
≥ 16
≥ 58

Bereiche als min – max; ≤ / ≥, wenn die Norm nur eine Grenze nennt, ≈ für Näherungswerte. Größen in (Klammern) möglichst vermeiden. Zeile wählen für das Größenblatt.

Helfen Sie, die nächsten 50 Normen zu verifizieren.

Jede Maßangabe braucht eine nachvollziehbare Quelle. Tragen Sie Fotos, Zeichnungen oder geprüfte Daten bei.

Mitwirken